Standards & guidance

Vertex Building Diagnostics

Thermal bridging and junction design: what does ISO 10211 help assess?

A practical introduction to 2D thermal-bridge modelling, heat-flow paths and internal surface temperatures at external-wall junctions.

Why do junctions need separate attention?

Changes in geometry and material continuity at window reveals, floor edges, balconies, parapets and wall-to-roof junctions can create localised heat-flow paths. These details can affect both overall heat loss and minimum internal surface temperature. A nominal insulation thickness alone cannot describe the performance of every junction.

What does ISO 10211 address?

ISO 10211:2017 specifies two- and three-dimensional modelling approaches for calculating heat flows and surface temperatures at thermal bridges. Depending on the project, outputs may include a linear thermal transmittance (ψ-value) and information needed to evaluate a detail's local surface-temperature performance.

A useful calculation starts with an agreed drawing and credible inputs: the actual build-up and geometry, material properties, boundary conditions and intended construction continuity. A model represents the detail and assumptions provided; it does not by itself prove how an existing junction was installed.

How might a model support a client?

  • Design review: compare proposed window-reveal, slab-edge or parapet details before installation.
  • Existing building investigation: compare plausible build-ups or remedial options where a cold junction has been reported, with limitations stated.
  • Reporting: separate a calculated result from measured site temperatures and from any conclusion about a concealed defect.

Where there is a concern about condensation or mould, surface-temperature calculations may need to be considered alongside indoor temperature and humidity using an appropriate risk-assessment method.

Do I need a thermal-bridge calculation?

Send Vertex a drawing or sketch, wall and insulation build-up, junction dimensions, intended purpose and any site observations. We can discuss an appropriate 2D junction review or calculation and define the deliverable before quoting. A project requiring formal third-party certification or a particular assessor's sign-off must be identified at the outset.

Primary reference: ISO 10211:2017 — heat flows and surface temperatures at thermal bridges

Enquire about a junction review

Discuss the right scope for your project

Tell us about the building concern, drawing detail or assessment brief. We will discuss the applicable technical scope and quote before work is agreed.

Send a building diagnostics enquiry

Further building diagnostics guidance